OptiNext Co., LTD.

<span style="color: rgba(0, 0, 0, 0.85); font-family: Inter, -apple-system, BlinkMacSystemFont, " segoe="" ui",="" "sf="" pro="" sc",="" display",="" icons",="" "pingfang="" "hiragino="" sans="" gb",=

Manufacturer from China
Site Member
1 Years
Home / Products / Huawei Base Station /

BBU5900

Contact Now
OptiNext Co., LTD.
Country/Region:china
Contact Now

BBU5900

Ask Latest Price
Video Channel
Brand Name :Huawei
Model Number :BBU5900
Place of Origin :China
MOQ :5
Payment Terms :T/T
Supply Ability :500pcs/Week
Delivery Time :15 working days
Contact Now

Add to Cart

Find Similar Videos
View Product Description

BBU5900 Equipment Specifications

BBU5900 equipment specifications include the input power specifications, dimensions, weight, heat dissipation capabilities, environmental specifications, and surge protection specifications.

Input Power

The following table lists the input power specifications of a BBU5900.
Table 1 Input power of a BBU5900

Item

Specifications

Input power type –48 V DC
Operating voltage –38.4 V DC to –57 V DC

Dimensions and Weight

The following table lists the dimensions and weight of a BBU5900.
Table 2 Dimensions and weight of a BBU5900

Item

Specifications

Dimensions (H x W x D) 86 mm x 442 mm x 310 mm (3.39 in. x 17.40 in. x 12.20 in.)
Weight 18 kg (39.69 lb) in full configuration

Heat Dissipation Capabilities

The following table lists the heat dissipation capability of a BBU5900.
Table 3 Heat dissipation capability of a BBU5900

Item

Specifications

Heat dissipation capability 2100 W (configured with a FANf)

Environmental Specifications

The following table lists the environmental specifications of a BBU5900.
Table 4 Environmental specifications of a BBU5900

Item

Specifications

Operating temperature Long-term operation: –20°C to +55°C (–4°F to +131°F)
Relative humidity 5% RH to 95% RH
Ingress protection rating IP20
Altitude ≤ 4000 m (13123.36 ft)
Noise sound power level

ETS 300 753 3.1

≤ 7.2 bels

Storage time Installed and used within one year

Compliance Standards

The following table lists the compliance standards for a BBU5900.
Table 5 Standards compliance for a BBU

Item

Standard

Safety standard
  • IEC/EN/UL60950-1
  • IEC/EN/UL62368-1
  • GB4943.1
Operating environment ETSI EN 300 019-1-3 Class3.1
Storage environment
ETSI EN 300 019-1-1 Class1.2
NOTE:
  • The validity period is one year.
  • The product can function properly within the validity period if the storage environment meets the preceding standards.
Surge protection
  • IEC 62305-1 Protection against lightning - Part 1: General principles
  • IEC 62305-3 Protection against lightning - Part 3: Physical damage to structures and life hazard
  • IEC 62305-4 Protection against lightning - Part 4: Electrical and electronic systems within structures
  • ITU-T K.35 Bonding configurations and earthing at remote electronic sites
  • ITU-T K.56 Protection of radio base stations against lightning discharges
  • ITU-T K.97 Lightning protection of distributed base stations
  • ETSI EN 300 253 Environmental Engineering (EE): Earthing and bonding configuration inside telecommunications centers
  • YD/T 2324-2011: Lightning protection requirements and test methods for radio base stations
  • GB 50689-2011 Code for design of lightning protection and earthing engineering for telecommunication bureaus (stations)
Inquiry Cart 0